Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex

Brand
Fluke
Model number
376 FC

True-rms 1000 A AC/DC clamp meter supplied with 18 in iFlex probe (2500 A AC); VFD filter, inrush, Fluke Connect.

Price and availability on request

Request a quote

Sent with the product details: Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Measures AC/DC current with included iFlex current probe
  • VFD low pass filter for accurate measurements of non-linear signals
  • Remotely log, trend and monitor to pinpoint intermittent faults
  • Inrush measurement to filter out noise and capture starting current

Specifications

AC Current via Jaw
Range999.9 A
Resolution0.1 A
Accuracy2% ±5 digits (10 Hz to 100 Hz); 2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz)3 @ 500 A; 2.5 @ 600 A; Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range2500 A
Resolution0.1 A (≤ 600 A); 1 A (≤ 2500 A)
Accuracy3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz)3.0 at 1100 A; 2.5 at 1400 A; 1.42 at 2500 A; Add 2% for C.F. > 2
DC Current
Range999.9 A
Resolution0.1 A
Accuracy2% ±5 digits
AC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V); 1 V (≤1000 V)
Accuracy1% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V); 1 V (≤1000 V)
Accuracy1% ±5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1% ±5 digits
Frequency via Jaw
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5% ±5 digits
Trigger level5 Hz to 10 Hz, ≥10 A; 10 Hz to 100 Hz, ≥5 A; 100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5% ±5 digits
Trigger level5 Hz to 20 Hz, ≥25 A; 20 Hz to 100 Hz, ≥20 A; 100 Hz to 500 Hz, ≥25 A
Resistance
Range60 kΩ
Resolution0.1 Ω (≤600 Ω); 1 Ω (≤6000 Ω); 10 Ω (≤60 kΩ)
Accuracy1% ±5 digits
Capacitance
Range1000 μF
Resolution0.1 μF (≤ 100 μF); 1 μ F (≤ 1000 μF)
Accuracy1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground1000 V
Batteries2 AA, NEDA 15A, IEC LR6
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity -, non-condensing (< 10°C)≤90% RH (at 10 °C to 30 °C); ≤75% RH (at 30 °C to 40 °C); ≤45% RH (at 40 °C to 50 °C)
Operating altitude2000 m
Storage altitude12,000 m
Size (L x W x H)249 x 85 x 45 mm
Weight395 g
Jaw opening34 mm
Flexible current probe diameter7.5 mm
Flexible current probe cable length (head to electronics connector)1.8 m
SafetyIEC 61010-1, Pollution Degree 2; IEC 61010-2-032: CAT III 1000 V; CAT IV 600 V; IEC 61010-2-033:CAT III 1000 V; CAT IV 600 V
Safety
IP ratingIEC 60529: IP30, non-operating
Supplied with
ContentsFluke 376 FC True-RMS Clamp Meter; 18-inch iFlex Flexible Current Probe; TPAK magnetic hanging strap; TL75 Test Leads; Two AA batteries (Installed); Soft carrying case; Coated instruction card

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 376 FC

The Fluke 376 FC is an advanced troubleshooting clamp meter for industrial and commercial electricians, supplied with an 18 in iFlex flexible current probe. It has a low-pass filter for non-linear signals and an inrush function, and through Fluke Connect it can log, trend and monitor readings remotely.