Extech SDL200 4-Channel Datalogging Thermometer
- Brand
- Extech
- Model number
- SDL200
- Category
- Data Loggers
The SDL200 records data on an SD card in Excel format. 4-Channel datalogging with 6 Thermocouple types (J, K, E, T, R,S) and 2-Channel datalogging with RTD (Pt100Ohm) probes. Displays [T1, T2, T3, T4] or differential [T1-T2] readings.
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- Memory: 20M data records using a 2G SD card
- Temperature (RTD): -327 to 1562 °F (-200 to 850 °C)
- Temperature (RTD) Basic Accuracy: ±0.4% of reading (+1.8°F/+1°C)
- Temperature (RTD) Max Resolution: 0.1°/1°
- Temperature (Type E): -58 to 1652°F (-50 to 900°C)
- Temperature (Type E) Basic Accuracy: ±0.4% of reading (+1.8 °F/+1 °C)
Specifications
| Memory | 20M data records using a 2G SD card |
|---|---|
| Temperature (RTD) | -327 to 1562 °F (-200 to 850 °C) |
| Temperature (RTD) Basic Accuracy | ±0.4% of reading (+1.8°F/+1°C) |
| Temperature (RTD) Max Resolution | 0.1°/1° |
| Temperature (Type E) | -58 to 1652°F (-50 to 900°C) |
| Temperature (Type E) Basic Accuracy | ±0.4% of reading (+1.8 °F/+1 °C) |
| Temperature (Type E) Max Resolution | 0.1 °F/ °C |
| Temperature (Type J) | -148 to 2102°F (-100 to 1150°C) |
| Temperature (Type J) Basic Accuracy | ±0.4% of reading (+1.8 °F/+1 °C) |
| Temperature (Type J) Max Resolution | 0.1 °F/ °C |
| Temperature (Type K) Basic Accuracy | ±0.4% of reading (+1.8 °F/+1 °C) |
| Temperature (Type K) Max Resolution | 0.1 °F/ °C |
| Temperature (Type R) | 32 to 3092°F (0 to 1700°C) |
| Temperature (Type R) Basic Accuracy | ±0.5% of reading (+2 °F/+1 °C) |
| Temperature (Type R) Max Resolution | 1 °F/ °C |
| Temperature (Type S) | 32 to 2732°F (0 to 1500°C) |
| Temperature (Type S) Basic Accuracy | ±0.5% of reading (+2 °F/+1 °C) |
| Temperature (Type S) Max Resolution | 1 °F/ °C |
| Temperature (Type T) | -58 to 752°F (-50 to 400°C) |
| Temperature (Type T) Basic Accuracy | ±0.4% of reading (+1.8 °F/+1 °C) |
| Temperature (Type T) Max Resolution | 0.1 °F/ °C |
| Temperature [Type K] | -148 to 2372°F (-100 to 1300°C) |
| Certifications | SDL200-NIST_S - CE, NIST SDL200_S - CE |
|---|---|
| Dimensions | 7.2 × 2.9 × 1.9" (182 × 73 × 47.5mm) |
| Power | 6 × AA (1.5V) batteries |
| Warranty | 3 years |
| Weight | 17.6oz (500g) |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details
About the SDL200
The SDL200 records data on an SD card in Excel format. 4-Channel datalogging with 6 Thermocouple types (J, K, E, T, R,S) and 2-Channel datalogging with RTD (Pt100Ohm) probes. Displays [T1, T2, T3, T4] or differential [T1-T2] readings. Offset adjustment used for zero function to make relative measurements. Stores 99 readings manually and 20M readings via 2G SD card. Records readings with real date and time stamp. User programmable sampling rate from 1 to 3600 seconds. Min/Max, Data Hold, Auto Power Off. Complete with 6 AA batteries, four general purpose Type K bead wire temperature probes, SD card, and hard carrying case.
Frequently asked questions
What is the Extech SDL200?
The SDL200 records data on an SD card in Excel format. 4-Channel datalogging with 6 Thermocouple types (J, K, E, T, R,S) and 2-Channel datalogging with RTD (Pt100Ohm) probes. Displays [T1, T2, T3, T4] or differential [T1-T2] readings.
What is the accuracy of the SDL200?
Temperature (RTD) Basic Accuracy: ±0.4% of reading (+1.8°F/+1°C); Temperature (Type E) Basic Accuracy: ±0.4% of reading (+1.8 °F/+1 °C); Temperature (Type J) Basic Accuracy: ±0.4% of reading (+1.8 °F/+1 °C).
What is the power rating of the SDL200?
6 × AA (1.5V) batteries.
What approvals does the SDL200 have?