Autonics UTRCM18-1300D Cylindrical Ultrasonic Sensor UTRCM18-1300D
- Brand
- Autonics
- Model number
- UTRCM18-1300D
- Category
- Distance & Displacement Sensors
Autonics UTRCM18-1300D cylindrical ultrasonic sensor (UTR Series): sensing distance 120 to 1300 mm, ≥ 0.175 mm resolution, ≤ 100 mA. Order code note: V1-12~30VDC.
Price and availability on request
Key features
- Detect and measure various material and surface types with ultrasonic sensing
- Sensing distance (by mount diameter); M18 Model: 30 to 350 mm /; 65 to 600 mm / 120 to 1,300 mm; M30 Model: 600 to 8,000 mm
- Temperature compensation (auto / manual) and detection width conversion function for high accuracy
- 316L stainless steel body for high corrosion resistance
- 360º ring type indicator to check operation status from any direction
- Digital output (Push-Pull) support
- IO-Link models, Simultaneous digital and analog output models available
- Configure settings and monitor status with ultrasonic sensor programming units (UT-P)
- Protection structure: IP66, IP67, IP68, IP69K (may vary by model)
Specifications
| Series | UTR Series |
|---|---|
| Order code description | V1-12~30VDC |
| Catalogue model group | UTRCM18-□1300D-□ |
| Sensing distance | 120 to 1300 mm |
|---|---|
| Blind zone | 0 to 115 mm |
| Foreground suppression | 120 to 360 mm |
| Max. setting zone | 1300 mm |
| Transducer frequency | 200 kHz |
| Switching frequency | ≥ 10 Hz |
| Response time | ≤ 100 ms |
| Hysteresis | 20 mm |
| Standard sensing target Aluminum | 200 × 200 mm |
| Resolution | ≥ 0.175 mm |
| Accuracy | ± 1 % F.S. |
| Repeat accuracy | ± 0.15 % F.S. |
| Weight (packaged) | ≈ 32 g (≈ 90 g) |
| Power supply | 12 - 30 VDC (ripple P-P: ≤ 10 %) |
| Current consumption | ≤ 45 mA (no load) |
| Digital output | Push-pull |
| Load voltage | ≤ 30 V |
| Load current | ≤ 100 mA |
| Residual voltage | ≤ 3 V |
| Analog output | [current output] DC 4 -20 mA / [voltage output] DC 0 - 10 V |
| Current output | ● |
| Load resistance | [voltage output] 12 - 30 VDC : ≥ 100 kΩ [current output] 12 - 20 VDC : ≤ 100 Ω / 20 - 30 VDC : ≤ 500 Ω |
| Protection circuit | Surge protection circuit, output short over current protection circuit, reverse polarity protection |
| Insulation resistance | ≥ 50 MΩ (500 VDC megger) |
| Dielectric strength | Between the charging part and the case: 1,000 VAC 50 / 60 Hz for 1 min |
| Vibration | 1.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours |
| Shock | 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times |
| Ambient temperature | -25 to 70 ℃, storage: -40 to 85 ℃ (no freezing or condensation) |
| Protection structure | UTRCM18-350, UTRCM18-600 : IP66, IP67 (IEC standard), IP69K (DIN standard), IP68 UTRCM18-1300: IP66, IP67 (IEC standard), IP69K (DIN standard) UTRCM30-8M: IP66, IP67 (IEC standard) |
| Connection | Connector models |
| Connector spec. | M12 5-pin plug connector |
| Material | Case: mount - SUS316L, body - PC transducer: polyurethane foam, epoxy resin with glass |
| Comm. protocol | IO-Link |
| Sold separately | Ultrasonic sensor programming unit: UT-P Series; M12 connector cable: CID5- , C1D5- |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.