Key features

  • 50 ms high-speed sampling rate and ± 0.3 % display accuracy
  • Large LCD display with easy-to-read white PV characters
  • Switch between current output and SSR drive output
  • SSR drive output (SSRP function) control options: ON / OFF control, cycle control, phase control
  • Communication output model available: RS485 (Modbus RTU)
  • Parameter configuration via PC (RS485 communication): DAQMaster software included (comprehensive device management software)
  • Compact, space-saving design with 45 mm depth: 30% rear-length size reduction compared to similar-sized (48 × 48 mm) models from Autonics Terminal protection cover sold separately: RSA-COVER

Specifications

Model
SeriesTX Series
Order code description100-240VAC 50/60Hz(N)(ENG)
Specifications
Power supply100 - 240 VAC 50/60 Hz
Permissible voltage range90 to 110 % of rated voltage
Power consumption≤ 8 VA
Sampling period50 ms
Input specificationRefer to Autonics website
Control output Relay250 VAC 3 A, 30 VDC 3 A, 1a
Control output SSRTX4S: 12 VDC ±2 V, ≤ 20 mA TX4M/H/L: 13 VDC ±3 V, ≤ 20 mA
Control output CurrentDC 4-20 mA or DC 0-20 mA (parameter), Load resistance: ≤ 500 Ω
Alarm output RelayAL1/2: 250 VAC 3 A 1a
Option output PV transmissionDC 4 - 20 mA (Load resistance: ≤ 500 Ω, Output Accuracy: ±0.3% F.S.)
Option output RS485 Comm.Modbus RTU
Display type11 Segment (Red, Green, Yellow), LCD type
Control type Heating, CoolingON/OFF, P, PI, PD, PID Control
Hysteresis1 to 100 (0.1 to 50.0) ℃/℉
Proportional band (P)0.1 to 999.9 ℃/℉
Integral time (I)0 to 9,999 sec
Derivative time (D)0 to 9,999 sec
Control cycle (T)0.5 to 120.0 sec
Manual reset0.0 to 100.0%
Relay life cycle Mechanical≥ 5,000,000 operations
Relay life cycle Electrical≥ 200,000 operations (resistance load: 250 VAC 3 A)
Dielectric strengthBetween the charging part and the case: 3,000 VAC 50/60 Hz for 1 min
Vibration0.75 mm amplitude at frequency 5 to 55Hz in each X, Y, Z direction for 2 hours
Insulation resistance≥ 100 MΩ (500 VDC megger)
Noise immunity±2 kV square shaped noise (pulse width 1 ㎲) by noise simulator R-phase, S-phase
Memory retention≈ 10 years (non-volatile semiconductor memory type)
Ambient temperature-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humidity35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)
Protection structureIP50 (Front panel, IEC standards)
Insulation typeDouble or reinforced insulation ( dielectric strength between primary circuit and secondary circuit: 3 kV)
Unit weight (packaged)• TX4S: ≈ 87 g (≈ 146 g) • TX4M: ≈ 143 g (≈ 233 g) • TX4H: ≈ 133 g (≈ 214 g) • TX4L: ≈ 206 g (≈ 290 g)