Autonics TNS-P42SR-RS-006 Two-Degree-of-Freedom PID Temperature Controller TNS-P42SR-RS-006

Model number
TNS-P42SR-RS-006

Autonics TNS-P42SR-RS-006 Two-Degree-of-Freedom PID temperature controller (TN Series): 100 - 240 VAC , 50/60 Hz supply, IP65 (Front panel, IEC standards). Order code note: V1-100-240VAC.

Price and availability on request

Request a quote

Sent with the product details: Autonics TNS-P42SR-RS-006 Two-Degree-of-Freedom PID Temperature Controller TNS-P42SR-RS-006.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 2-DOF PID algorithm optimized for various control environments
  • 50 ms high-speed sampling and ± 0.2% display accuracy
  • Program control and fixed control models available; Up to 10 patterns X 20 steps program setting (program control model); Timer function for preset operation (fixed control model)
  • Simultaneous heating / cooling and automatic / manual control function
  • Control functions: Group PID, Zone PID, Anti Reset Windup (ARW)
  • Control status monitoring of up to 10 events
  • RS485 communication output model available; Communication protocols: Modbus RTU / ASCII, PLC ladderless, Sync-Master; Communication speed: up to 115,200bps
  • Parameter setting via PC

Specifications

Model
SeriesTN Series
Order code descriptionV1-100-240VAC
Specifications
Power supply100 - 240 VAC , 50/60 Hz
Permissible voltage range90 to 110 % of rated voltage
Power consumption≤ 8 VA
Display type11 segment, LCD type (operating value display part: 7 segment)
Sampling period50 / 100 / 250 ms (parameter)
Input specificationRefer to Autonics website
Option input CT• 0.0-50.0 A (primary current measurement range) • CT ratio: 1/1,000 • Measurement accuracy: ±5% F.S. ±1digit
Option input Digital• Contact - ON: ≤ 2 kΩ, OFF: ≥ 90 kΩ • Non contact - residual voltage ≤ 1.0 V, leakage current ≤ 0.1 mA • Outflow current: ≈ 0.5 mA per input
Control output Relay250 VAC 3A 1a
Control output SSR12 VDC ±2 V, ≤ 20 mA
Control output CurrentDC 0 - 20 mA or DC 4 - 20 mA (parameter), Load resistance: ≤ 500 Ω
Option output Alarm250 VAC 3 A 1a
Option output TransmissionDC 4 - 20 mA (load resistance: ≤ 500 Ω, output accuracy: ±0.3% F.S.)
Option output CommunicationRS485
Control type TypeON/OFF, P, PI, PD, PID
Control type Multi SV≤ 4 SV
Control type Group PID≤ 8 group
Control type Zone PID4 zones
Control type ARW (Anti Reset Windup)50 to 200 %
Program control Program≤ 10 patterns
Program control Step≤ 200 steps (1 pattern: ≤ 20 steps)
Program control Setting typeTime setting
Hysteresis• Thermocouple, RTD: 1 to 100 (0.1 to 100.0) ℃/℉ • Analog: 1 to 100 digit
Proportional band (P)0.1 to 999.9 ℃ (0.1 to 999.9%)
Integral time (I)0 to 9,999 sec
Derivative time (D)0 to 9,999 sec
Control cycle (T)• Relay / SSRP output: 0.1 to 120.0 sec • Selectable current or SSR drive output: 1.0 to 120.0 sec
Manual reset0.0 to 100.0%
Dielectric strengthBetween the charging part and the case: 3,000 VAC 50/60 Hz for 1 min
Vibration0.75 mm amplitude at frequency of 5 to 55 Hz in each X, Y, Z direction for 2 hours
Relay life cycle Mechanical• OUT1/2: ≥ 5,000,000 operations • AL1/2/3/4/5/6: ≥ 20,000,000 operations
Relay life cycle Electrical• OUT1/2: ≥ 200,000 operations • AL1/2/3/4/5/6: ≥ 100,000 operations
Insulation resistance≥ 100 MΩ (500 VDC megger)
Insulation typeDouble insulation or reinforced insulation ( dielectric strength between the measuring input part and the power part: 3 kV)
Noise immunity±2 kV square shaped noise by noise simulator (pulse width: 1 ㎲) R-phase, S-phase
Memory retention≈ 10 years (non-volatile semiconductor memory type)
Ambient temperature-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humidity35 to 85%RH
Protection structureIP65 (Front panel, IEC standards)
AccessoryBracket
Unit weight (packaged)• TNS: ≈ 128 g (≈ 156 g) • TNH: ≈ 184 g (≈ 286 g) • TNL: TNL: ≈ 301 g (≈ 443 g)
Comm. protocolModbus RTU/ASCII, Sync-Master, PLC ladderless
Accessories
Sold separatelyFront cover: FSA / FHA / FLA-COVER; Terminal protection cover: RSA / RMA / RHA / RLA-COVER; Communication Converter: SCM-US / SCM-38I / SCM-US48I / SCM-WF48; Current transformer (CT)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.