| Power supply | 100 - 240 VAC , 50/60 Hz |
|---|
| Permissible voltage range | 90 to 110 % of rated voltage |
|---|
| Power consumption | ≤ 8 VA |
|---|
| Display type | 11 segment, LCD type (operating value display part: 7 segment) |
|---|
| Sampling period | 50 / 100 / 250 ms (parameter) |
|---|
| Input specification | Refer to Autonics website |
|---|
| Option input CT | • 0.0-50.0 A (primary current measurement range) • CT ratio: 1/1,000 • Measurement accuracy: ±5% F.S. ±1digit |
|---|
| Option input Digital | • Contact - ON: ≤ 2 kΩ, OFF: ≥ 90 kΩ • Non contact - residual voltage ≤ 1.0 V, leakage current ≤ 0.1 mA • Outflow current: ≈ 0.5 mA per input |
|---|
| Control output Relay | 250 VAC 3A 1a |
|---|
| Control output SSR | 12 VDC ±2 V, ≤ 20 mA |
|---|
| Control output Current | DC 0 - 20 mA or DC 4 - 20 mA (parameter), Load resistance: ≤ 500 Ω |
|---|
| Option output Alarm | 250 VAC 3 A 1a |
|---|
| Option output Transmission | DC 4 - 20 mA (load resistance: ≤ 500 Ω, output accuracy: ±0.3% F.S.) |
|---|
| Option output Communication | RS485 |
|---|
| Control type Type | ON/OFF, P, PI, PD, PID |
|---|
| Control type Multi SV | ≤ 4 SV |
|---|
| Control type Group PID | ≤ 8 group |
|---|
| Control type Zone PID | 4 zones |
|---|
| Control type ARW (Anti Reset Windup) | 50 to 200 % |
|---|
| Program control Program | ≤ 10 patterns |
|---|
| Program control Step | ≤ 200 steps (1 pattern: ≤ 20 steps) |
|---|
| Program control Setting type | Time setting |
|---|
| Hysteresis | • Thermocouple, RTD: 1 to 100 (0.1 to 100.0) ℃/℉ • Analog: 1 to 100 digit |
|---|
| Proportional band (P) | 0.1 to 999.9 ℃ (0.1 to 999.9%) |
|---|
| Integral time (I) | 0 to 9,999 sec |
|---|
| Derivative time (D) | 0 to 9,999 sec |
|---|
| Control cycle (T) | • Relay / SSRP output: 0.1 to 120.0 sec • Selectable current or SSR drive output: 1.0 to 120.0 sec |
|---|
| Manual reset | 0.0 to 100.0% |
|---|
| Dielectric strength | Between the charging part and the case: 3,000 VAC 50/60 Hz for 1 min |
|---|
| Vibration | 0.75 mm amplitude at frequency of 5 to 55 Hz in each X, Y, Z direction for 2 hours |
|---|
| Relay life cycle Mechanical | • OUT1/2: ≥ 5,000,000 operations • AL1/2/3/4/5/6: ≥ 20,000,000 operations |
|---|
| Relay life cycle Electrical | • OUT1/2: ≥ 200,000 operations • AL1/2/3/4/5/6: ≥ 100,000 operations |
|---|
| Insulation resistance | ≥ 100 MΩ (500 VDC megger) |
|---|
| Insulation type | Double insulation or reinforced insulation ( dielectric strength between the measuring input part and the power part: 3 kV) |
|---|
| Noise immunity | ±2 kV square shaped noise by noise simulator (pulse width: 1 ㎲) R-phase, S-phase |
|---|
| Memory retention | ≈ 10 years (non-volatile semiconductor memory type) |
|---|
| Ambient temperature | -10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation) |
|---|
| Ambient humidity | 35 to 85%RH |
|---|
| Protection structure | IP65 (Front panel, IEC standards) |
|---|
| Accessory | Bracket |
|---|
| Unit weight (packaged) | • TNS: ≈ 128 g (≈ 156 g) • TNH: ≈ 184 g (≈ 286 g) • TNL: TNL: ≈ 301 g (≈ 443 g) |
|---|
| Comm. protocol | Modbus RTU/ASCII, Sync-Master, PLC ladderless |