Autonics SRHL1-4420 Single-Phase Alarm Output SSR with Integrated Heatsink SRHL1-4420
- Brand
- Autonics
- Model number
- SRHL1-4420
- Category
- Solid State Relays
Autonics SRHL1-4420 Single-Phase alarm output SSR with integrated heatsink (SRHL1 Series): 20 Arms load, ≤ 50 mA. Order code note: 90-240VAC, 48-480VAC 20A(ZC).
Price and availability on request
Key features
- Rated input voltage: 10 - 30 VDC , 90 - 240 VAC
- Rated load voltage: 24 - 240 VAC , 48 - 480 VAC
- Rated load current: 10 A, 15 A, 20 A, 25 A, 40 A
- Zero cross turn-on / Random turn-on models available
- Input indicator (green)
- Overheat prevention function; Rated load current 10 / 15 / 20 / 25 A:; alarm indicator (red); Rated load current 40 A:; alarm output indicator (red), alarm output
- DIN Rail or panel mount installation
Specifications
| Series | SRHL1 Series |
|---|---|
| Order code description | 90-240VAC, 48-480VAC 20A(ZC) |
| Rated input voltage range | 90 - 240 VACrms (50 / 60 Hz) |
|---|---|
| Allowable input voltage range | 85 - 264 VACrms (50 / 60 Hz) |
| Max. input current | 22 mA |
| Operating voltage | ≥ 85 VACrms |
| Releasing voltage | ≤ 10 VACrms |
| Operating time Zero cross turn-on | ≤ 2 cycle of load power + 1 ms |
| Releasing time | ≤ 2 cycle of load power + 1 ms |
| Rated load voltage range | 48 - 480 VACrms (50 / 60 Hz) |
| Allowable load voltage range | 48 - 528 VACrms (50 / 60 Hz) |
| Rated load current Resistive load (AC-51) | 20 Arms |
| Min. load current | 0.5 Arms |
| Max. 1 cycle surge current (60 Hz) | 500 A |
| Max. non-repetitive surge current (I2t, t = 8.3 ms) | 1000 A2s |
| Peak voltage (non-repetitive) | 1200 V (zero cross turn-on), 1000 A (random turn-on) |
| Leakage current (Ta = 25 ℃) | ≤ 10 mArms (480 VAC /60 Hz) |
| Output ON voltage drop [Vpk] (max. load current) | ≤ 1.6 V |
| Static off state dv/dt | 500 V/μs |
| Load voltage | ≤ 30 VDC |
| Load current | ≤ 50 mA |
| Turn-off time | ≤ 100 ms |
| Dielectric strength (Vrms) | Between the charging part and the case: 4,000 VAC 50 / 60 Hz for 1 min |
| Insulation resistance | Input-output, input/output-case: ≥ 100 MΩ (500 VDC megger) |
| Indicator | Input indicator (green), alarm indicator (red) |
| Vibration | 0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 1 hour |
| Vibration (malfunction) | 0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 10 min |
| Shock | 300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times |
| Shock (malfunction) | 100 m/s2 (≈ 10 G) in each X, Y, Z direction for 3 times |
| Ambient temperature | -30 to 70 ℃, storage: -30 to 100 ℃ (no freezing or condensation) |
| Ambient humidity | 45 to 85 %RH, storage: 45 to 85 %RH (no freezing or condensation) |
| Input terminal connection | ≥ 1×0.5 mm2 (1×AWG 20), ≤ 1×4 mm2 (1×AWG 12) or ≤ 2×1.5 mm2 (2×AWG 16) |
| Output terminal connection | Rated load current 10 / 15 / 20 / 25 A : ≥ 1×0.75 mm2 (1×AWG 18), ≤ 1×6 mm2 (1×AWG 10) or ≤ 2×2.5 mm2 (2×AWG 14) Rated load current 40 A : ≥ 1×1.5 mm2 (1×AWG 16), ≤ 1×16 mm2 (1×AWG 6) or ≤ 2×6 mm2 (2×AWG 10) |
| Input terminal fixed torque | 0.75 to 0.95 N m |
| Output terminal fixed torque | Rated load current 10 / 15 / 20 / 25 A: 1.0 to 1.35 N m Rated load current 40 A: 1.6 to 2.2 N m |
| Weight (packaged) | Rated load current 10 / 15 / 20 / 25 A: ≈ 192 g (≈ 270 g) Rated load current 40 A: ≈ 372 g (≈ 468 g) |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.