Autonics SPR1-4100NFF Single-Phase / 3-Phase Slim Power Controller SPR1-4100NFF

Model number
SPR1-4100NFF

Autonics SPR1-4100NFF Single-Phase / 3-Phase slim power controller (SPR Series): 25 / 35 / 50 / 70 / 100 /150 A load, 3-digit 7segment LED display. Order code note: SPR1/440V/100A None/P-FB/Fuse.

Price and availability on request

Request a quote

Sent with the product details: Autonics SPR1-4100NFF Single-Phase / 3-Phase Slim Power Controller SPR1-4100NFF.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Slim and elegant design
  • LED display allows real-time monitoring of control input, load voltage, load current, load power, load resistance and heat-sink temperature
  • Stable control with feedback control (constant current, constant voltage, constant power)
  • Communication output models available: RS485 (Modbus RTU)
  • Parameter configuration via PCs (RS485): Free device management software (DAQMaster)
  • Various alarm functions (alarm output): over current, over voltage, heater disconnection, fuse break, heat-sink over heat, diode (SCR) error
  • Easy installation with mounting brackets
  • Easy fuse replacement and maintenance
  • High performance SCR (IXYS) diode

Specifications

Model
SeriesSPR Series
Order code descriptionSPR1/440V/100A None/P-FB/Fuse
Catalogue model groupSPR1-4□
Specifications
Control phaseSingle-phase
Rated load voltage440 VAC 50 / 60 Hz
Rated load current25 / 35 / 50 / 70 / 100 /150 A
Display method3-digit 7segment LED
IndicatorsOperation / manual control indicator (green) Alarm / output / unit (V, A) indicator (red)
Auto control inputCurrent: DC 4 - 20 mA, voltage: 1 - 5 VDC , contact (non-voltage): ON / OFF, contact (voltage): 5 - 12 VDC , communi cation: RS485
Manual control inputExternal adjuster (10 kΩ), output control adjuster (OUT ADJ)
Digital input (DI)RUN / STOP selectable, AUTO / MAN selectable, RESET
Alarm output250 VAC 3 A, 30 VDC 3 A, 1c resistance load
RS485 comm. outputModbus RTU method
Cooling methodRated load current 25 / 35 / 50 A: natural cooling Rated load current 70 / 100 / 150 A: forced air cooling (with cooling fan)
Unit weight (packaged)Rated load current 25 / 35 / 50 A: ≈ 1.3 kg (≈ 1.6 kg) Rated load current 70 A: ≈ 1.35 kg (≈ 1.65 kg) Rated load current 100 / 150 A: ≈ 2.8 kg (≈ 3.2 kg)
Control methodON/OFF control
Applied loadResistance load, inductive load
Output range0 / 100 %
Output accuracyVaries by control mode
Power supply100 - 240 VAC ± 10 % 50 / 60Hz ; 100 - 240 VAC ±10 % 50 / 60 Hz
Permissible voltage range90 to 110 % of rated voltage
Min. load current1 A
Power consumptionRated load current 25 / 35 / 50 A: ≤ 7 VA Rated load current 70 / 100 / 150 A: ≤ 12 VA ; Rated load current 25 / 35 / 50 A: ≤ 14 VA Rated load current 70 A: ≤ 22 VA Rated load current 100 / 150 A: ≤ 32 VA
Insulation resistance≥ 200 MΩ (500 VDC megger)
Dielectric strengthBetween the charging part and the case: 2,000 VAC 50 / 60 Hz for 1 min
Output leakage currents≤ 10 mArms
Noise immunity±2 kV square wave noise (pulse width: 1 ㎲) by the noise simulator
Memory retention≈ 10 years (when using non-volatile semiconductor memory type)
Vibration0.75 mm double amplitude at frequency of 5 to 55 Hz in each X, Y, Z direction for 2 hours
Vibration (malfunction)0.5 mm double amplitude at frequency of 5 to 55 Hz in each X, Y, Z direction for 10 min
Ambient temp.-10 to 55 ℃, storage: -20 to 80 ℃ (no freezing or condensation)
Ambient humi.35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Comm. protocolModbus RTU
Phase control output accuracyNormal control: within ± 10 % F.S. of rated load voltage Constant current feedback control: within ± 3 % F.S. of rated load current Constant voltage feedback control: within ± 3 % F.S. of rated load voltage Constant power feedback control: within ± 3 % F.S. of rated load power

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.