Autonics MT4N-DA-EN 4-Digit Multi Panel Meter MT4N-DA-EN
- Brand
- Autonics
- Model number
- MT4N-DA-EN
- Category
- Panel Meters
Autonics MT4N-DA-EN 4-Digit multi panel meter (MT4N Series): DC current input, 12 - 24 VDC , 12 - 24 VAC 50 / 60 Hz supply. Order code note: 12-24VDC/AC-1.
Price and availability on request
Key features
- Various input / output options (by model); Input options: DC voltage, DC current, AC voltage, AC current; Output options: RS485 communication output, transmission output (DC 4 - 20 mA), NPN / PNP open collector output, relay contact output (default option: indicator / no output)
- Maximum allowed input: 50 VDC , DC 500 mA, 250 VAC , AC 5A
- Display range: -1999 to 9999
- High / low-limit display scale function
- AC frequency measurement (range: 0.1 to 9999 Hz)
- Various functions: peak display value monitoring, display cycle delay, zero-point adjustment, peak display value correction, PV transmission output (DC 4 - 20 mA) scale, etc.
- Power supply: 12 - 24 VDC / VAC , 100 - 240 VAC
Specifications
| Series | MT4N Series |
|---|---|
| Order code description | 12-24VDC/AC-1 |
| Catalogue model group | MT4N-DA-□ |
| Input type | DC current |
|---|---|
| Max. allowable input | Dependent on the input type |
| DC input | -5 to 110 % F.S. for each measured input range |
| AC input | 10 to 110 % F.S. for each measured input range |
| Display method | 7-segment (red) LCD (character height: 9 mm) |
| Display accuracy | Dependent on the ambient temperature; 23 ± 5 ℃: ± 0.1 % F.S. rdg ± 2 digit; -10 to 50 ℃: ± 0.5 % F.S. rdg ± 3 digit |
| Max. display range | -1999 to 9999 (4 digit) |
| A / D conversion method | ΣΔ (Sigma Delta) ADC |
| Sampling cycle | 50 ms |
| Unit weight (packaged) | ≈ 64 g (≈ 127 g) |
| Preset output | None (indicator) / Relay / NPN open collector / PNP open collector output model |
| Relay | Contact capacity: 125 VAC 0.3 A, 30 VDC 1 A Contact composition: N.O ( 1a) |
| NPN / PNP open collector | Output capacity: ≤ 12 - 24 VDC ± 2 VDC , 50 mA resistive load |
| Sub output | None (indicator) / Transmission (DC 4 - 20 mA) / RS485 communication output model |
| Transmission (DC 4 - 20 mA) | Resolution: 1/12,000 (load resistance: ≤ 600 Ω) Response time: ≤ 500 ms Output accuracy (23 ± 5 ℃): ± 0.3 % F.S. |
| RS485 communication | Protocol: Modbus RTU |
| Power supply | 12 - 24 VDC , 12 - 24 VAC 50 / 60 Hz |
| Permissible voltage range | 90 to 110 % of rated voltage |
| Power consumption | 3 W / 5 VA |
| Insulation resistance | Between external terminal and case: ≥ 20 MΩ (500 VDC megger) |
| Dielectric strength | Between the charging part and the case : 2,000 VAC 50 / 60 Hz for 1 min |
| Noise immunity | ± 500 V square wave noise (pulse width: 1 ㎲) by the noise simulator |
| Vibration | 0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours |
| Vibration (malfunction) | 0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 10 min |
| Shock | 300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times |
| Shock (malfunction) | 100 m/s2 (≈ 10 G) in each X, Y, Z direction for 3 times |
| Relay life cycle | Mechanical: ≥ 5,000,000 operations Electrical: ≥ 100,000 operations (125 VAC 0.3A resistive load) |
| Ambient temp. | -10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation) |
| Ambient humi. | 35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation) |
| Insulation type | Symbol: , double or reinforced insulation (dielectric strength between the measurement input part and the power part: 1 kV) |
| Comm. protocol | Modbus RTU |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.