Autonics M4N-DV-13 Panel Meter (Indicator) M4N-DV-13

Model number
M4N-DV-13
Category
Panel Meters

Autonics M4N-DV-13 panel meter (Indicator) (M4N Series): DC voltage input, 5 VDC / 12 - 24 VDC model supply. Order code note: DC19.99V.

Price and availability on request

Request a quote

Sent with the product details: Autonics M4N-DV-13 Panel Meter (Indicator) M4N-DV-13.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Input options (by model); Input options: DC voltage, DC current
  • Auto-zero adjustment and hold display value function
  • Max display value: 1999
  • 7-segment LED display
  • Compact size: DIN W 48 × H 24 mm
  • Power supply: 5 VDC , 12 - 24 VDC

Specifications

Model
SeriesM4N Series
Order code descriptionDC19.99V
Catalogue model groupM4N-DV-□
Specifications
Input typeDC voltage
Max. allowable input≈ 150 % F.S. for each measured input range
Display method7-segment (red) LED (character height: 10 mm)
Display accuracy0.2 % F.S. rdg ± 1-digit
Sampling time2.5 times / sec
Display scale-1999 (4-digit)
Operation methodDual integral method
Sampling cycle300 ms
Response speed≈ 2 sec (0 to 1999)
Unit weight≈ 44 g
Power supply5 VDC / 12 - 24 VDC model
Permissible voltage range90 to 110 % of rated voltage
Power consumption2 W
Insulation resistance≥ 100 MΩ (500 VDC megger)
Dielectric strengthBetween the charging part and the case: 2,000 VAC 50 / 60 Hz for 1 min
Noise immunity±100 V square wave noise (pulse width: 1 ㎲) by the noise simulator
Vibration0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 1 hours
Vibration (malfunction)0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 10 min
Shock300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times
Shock (malfunction)100 m/s2 (≈ 10 G) in each X, Y, Z direction for 3 times
Ambient temperature-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humidity35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.