Key features

  • Max. counting speed: 20 cps
  • Compact rear-length size (64.5 mm)
  • Count up to 30 channels (individual output indicators for each channel)
  • 6-digit display (0 to 999999 range)
  • Front panel button lock function

Specifications

Model
SeriesCM6M Series
Order code description(N)24VDC
Catalogue model groupCM6M-30B2□
Specifications
Display digitsCounting / Setting value display: 6-digit CH display: 2-digit
Display method7-segment LED method - Counting value / CH display: red - Alarm output indicator / Setting value display: green
Alarm output indicator (W×H)2.7 × 3.3 mm
Character size (W × H)Setting value display: 5.5 × 11 mm Counting value display: 8 × 16 mm
Number of channelsMax. 30CH
Max. counting speed20 cps
Counting range0 to 999999
Min. signal widthRESET signal: ≥ 100 ms Counting value signal: ≥ 50 ms
Input methodBCD code (positive logic)
Input level[H]: 16 - 30 VDC , [L]: 0 - 3 VDC
Alarm outputContact / Solid state
TypeSPST (1a) × 1 / NPN open collector output × 1
Capacity250 VAC 3 A resistive load / ≤ 30 VDC 100 mA
Unit weight (packaged)≈ 145 g (≈ 215 g)
Power supply24 VDC
Permissible voltage range90 to 110 % of rated voltage
Power consumption2.6 W
Memory retention≈ 10 years (non-volatile semiconductor memory type)
Insulation resistance≥ 100 MΩ (500 VDC megger)
Dielectric strengthBetween the charging part and the case : 2,000 VAC 50 / 60 Hz for 1 minute
Noise immunity± 500 V square wave noise (pulse width: 1 ㎲) by the noise simulator
Vibration0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 1 hour
Vibration (malfunction)0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 10 min
Shock300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times
Shock (malfunction)100 m/s2 (≈ 10 G) in each X, Y, Z direction for 3 times
Relay life cycleMechanical: ≥ 10,000,000 operations Electrical: ≥ 100,000 operations
Ambient temperature-15 to 55 ℃, storage: -25 to 65 ℃ (no freezing or condensation)
Ambient humidity35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Protection structureIP54 (front part, IEC standard)