Adi-Artech 90610-B-P Pancake Load Cell - Precision Grade
- Brand
- Adi-Artech
- Model number
- 90610-B-P
- Category
- Load Cells
Adi-Artech strain gauge pancake load cell - precision grade, 0.5 Tf to 300 Tf for compression loads, in stainless steel, IP65 sealed. For compression testing, tablet hardness tester, calibration of other load cells & utms.
Price and availability on request
Key features
- Avavailable in capacity 0.5Tf. to 300 Tf
- Standard output 2.0 mV/V
- Complete environment protection IP 65 class
- Optional IP 68 available on request
- Dual bridge configuration available on request
Specifications
| Applications | Compression Testing, Tablet Hardness Tester, Calibration of other load cells & UTMs, Force & Impact Testing, Tank, Silo weighing, Robotics & Automation |
|---|
| Capacity range | 0.5Tf. to 300 Tf |
|---|---|
| Load direction | Compression Only |
| Standard capacities | 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30, 50, 75, 100, 150, 200, 300 Tf |
| Non-Linearity | < ±0.1% FSO (Full Scale Output) 10% to 100% range |
|---|---|
| Hysteresis | < ±0.15% FSO |
| Non-Repeatability | < ±0.01% FSO |
| Creep (30 minutes) | < ±0.04% FSO |
| Zero Balance | ±1.0% FSO |
| Nominal Output | 2.0 mV/V |
|---|---|
| Excitation Voltage | 10 VDC- Maximum 15 VDC |
| Input Resistance | 390 ± 10 Ohms up to 1000 Kgf 770 ± 20 Ohms 1.5 T & Above |
| Output Resistance | 350 ± 5 Ohms up to 1000 Kgf 700 ± 7 Ohms 1.5 T & Above |
| Insulation Resistance(50VDC) | > 1000 Mega Ohms(50 VDC) |
| Cable Length | 5 meters |
| Safe Overload of Rated | 150% |
|---|---|
| Ultimate Overload of Rated | 200% |
| Deflection | < 0.4 mm at FSO |
| Environmental Protection Class | IP65 |
| Compensated Temperature | 10-50 °C |
|---|---|
| Temperature Effect Output | < 0.005% FSO/ °C |
| Temperature Effect Zero | < 0.005% FSO/ °C |
| Dual Bridge | Redundancy for uninterrupted measurement in critical applications |
|---|---|
| Digital Version | Digital Output |
| Compatible Instrument | DLC-6M, DLC-6, Summing Junction Box |