Adi-Artech 70210 Double Ended Shear Beam Load Cell - Center Loaded End Supported

Model number
70210
Category
Load Cells

Adi-Artech strain gauge double ended shear beam load cell - center loaded end supported, 0-2.5 Tf to 0-100 Tf for compression loads, in SS 17-4 PH stainless steel, IP68 sealed. For silo weighing, onboard weighing, weigh bridge scale.

Price and availability on request

Request a quote

Sent with the product details: Adi-Artech 70210 Double Ended Shear Beam Load Cell - Center Loaded End Supported.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • End mounted and center loaded design provides better stability and accuracy
  • It is temperature compensated for 10 - 50 Deg. C
  • High accuracy available As per standard ISO 376:2011
  • Triple Sealing for environmental Protection
  • Complete Environmental Protection – Meets IP 65, IP 67 & or IP 68 class
  • Electro less nickel-plated tool steel & stainless steel constructions
  • A high-temperature version can be provided on request
  • Wide range of capacities from 2.5 TF to 100 TF
  • Standardized output (2.0 mV/V) and customized output can be provided on request
  • Calibration in mV/V/Ω
  • Can be customized to suit customer’s need

Specifications

Product
ApplicationsSilo Weighing, Onboard Weighing, Weigh Bridge Scale, Large Platform Scales, Truck, Tank & Hopper weighing
Rating
Capacity range0-2.5 Tf to 0-100 Tf
Load directionCompression only
Standard capacities2.5, 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 65, 75, 100, 125 -TF
Performance
Non-Linearity<±0.05% FSO (Full Scale Output)
Hysteresis<±0.03% FSO
Non-Repeatability<±0.02% FSO
Creep (30 minutes)< ±0.03%FSO
Zero Balance± 1.5 % FSO
Electrical
Output3.00 mV/V (Customized Output available on request)
Excitation VoltageMaximum 15 VDC (Suggested 5VDc / 10VDc)
Input Resistance770 ± 20.0 Ohms
Output Resistance700 ± 2 Ohms
Insulation Resistance(100 VDC) > 1000 Mega Ω (Ohms)
Structure
Safe Overload Of Rated Capacity150%
Ultimate Overload of Rated Capacity200%
Allowable Side Load50%
Deflection< 0.5 mm at FSO
Finish ProductElectro less nickel-plated tool steel / SS 17-4 PH
IP ratingIP68 (as per IS/IEC 60529:2001)
Temperature
Operating Temperature0°C to 60°C (Optional 90°C, 120°C, 150°C)
Compensated Temperature10°C to 50°C (Optional 90°C, 120°C, 150°C)
Temperature Effect Output< 0.0015%FSO/ °C
Temperature Effect Zero< 0.0020%FSO/ °C
Options
AtexII 3D EX tc IIIC T60°C DC , II 3G EX ec IIC GC
High Temperature Range40°C to 90°C (Temperature Effect on Output & Zero : < 0.020% FSO/ °C)
High Temp. CableTeflon Cable
Extra cable lengthSpecify extra length In Meters
Mounting AccessoriesWM-II
Digital VersionDigital Output
AccessoriesDLC-6 / DLC-6M / HH-06 DIGITAL LOAD CONTROLLER (MULTI. O/P)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.