Adi-Artech 60610 Single Point Miniature Load Cell

Model number
60610
Category
Load Cells

Adi-Artech strain gauge single point miniature load cell, 0-100 Gmf to 0-2000 Gmf for compression loads, in aluminium, IP65 sealed. For precision jewelry scales, small bagging machines, thread tension measurement.

Price and availability on request

Request a quote

Sent with the product details: Adi-Artech 60610 Single Point Miniature Load Cell.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Single Point Capability with Minimum Off- center Error
  • Moisture Protecting Sealing
  • Complete Environmental Protection – Meets IP 65 class
  • Aluminum Alloy constructions
  • Inbuilt Mechanical over load Protection Bracket
  • Wide range of capacities from 100 Gram F to 2 KGF
  • Calibration in mV/V/Ω

Specifications

Product
ApplicationsPrecision jewelry Scales, Small Bagging Machines, Thread Tension Measurement
Rating
Capacity range0-100Gmf to 0-2000Gmf
Load directionCompression only
Standard capacities100, 200, 300, 400, 500, 750, 1000, 1500, 2000 – Gmf
Performance
Non-Linearity< ±0.025% FSO (from 4% to 100% range)
Hysteresis< ±0.02%FSO
Non-Repeatability< ±0.01%FSO
Creep (30 minutes)< ±0.03%FSO
Zero Balance±1.0%FSO
Electrical
Output1.6 mV/V ± 0.2%
Excitation VoltageMaximum 15 VDC (Suggested 5VDc / 10VDc)
Input Resistance420 ± 15.0 Ω (Ohms)
Output Resistance350 ± 5.0 Ω (Ohms)
Insulation Resistance(100 VDC) > 1000 Mega Ω (Ohms)
Structure
Safe Overload Of Rated Capacity150%
Ultimate Overload of Rated Capacity250%
Allowable Side Load50%
Deflection< 0.4 mm at FSO
Platter Size120 mm dia
Finish ProductAluminum Alloy
IP ratingMeets IP 65 (as per IS/IEC 60529:2001)
Mechanical ProtectionBracket provided for over and under load protection
Temperature
Operating Temperature0°C to 55°C
Compensated Temperature10°C to 50°C
Temperature Effect Output< 0.0015 % FSO/ °C
Temperature Effect Zero< 0.0020 % FSO/ °C
Eccentric Load Effect< 0.025 % of FSO when 1/3 rated load placed within 120 mm radius from center of load cell
Options
Extra cable lengthSpecify extra length In Meters
Digital VersionDigital Output
Compatible InstrumentDLC-6M, DLC-6, Summing Junction Box

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.