Adi-Artech 60610-L Single Point Off-Center Load Cell
- Brand
- Adi-Artech
- Model number
- 60610-L
- Category
- Load Cells
Adi-Artech strain gauge single point off-center load cell, 0-200 Gmf to 0-2000 Gmf for compression loads, in aluminium, IP65 sealed. For table top weigh scale.
Price and availability on request
Key features
- Single Point Capability with minimum off center error Low Profile Design Capacity as low as 200Gmf
- full scale
- Moisture Protecting sealing
Specifications
| Applications | Table Top Weigh Scale |
|---|
| Capacity range | 0-200Gmf to 0-2000Gmf |
|---|---|
| Load direction | Compression only |
| Standard capacities | 0.2, 0.3, 0.4, 0.6, 1.0, 1.5, 2.0 – Kgf |
| Non-Linearity | < ±0.025% FSO (from 4% to 100% range) |
|---|---|
| Hysteresis | < ±0.02%FSO |
| Non-Repeatability | < ±0.01%FSO |
| Creep (30 minutes) | < ±0.03%FSO |
| Zero Balance | ±1.0%FSO |
| Output | 3.00 mV/V±0.05% (Customized Output available on request) |
|---|---|
| Excitation Voltage | 10 VDC- Maximum 15 VDC |
| Input Resistance | 420 ± 20 Ohms |
| Output Resistance | 350 ± 10 Ohms |
| Insulation Resistance | > 1000 Mega Ohms |
| Safe Overload Of Rated Capacity | 150% |
|---|---|
| Ultimate Overload of Rated Capacity | 250% |
| Allowable Side Load | 50% |
| Deflection | < 0.4 mm at FSO |
| Finish Product | Aluminum Alloy |
| IP Rating | IP65 |
| Operating Temperature | 0°C to 60°C |
|---|---|
| Compensated Temperature | 10-50 0C |
| Temperature Effect Output | < 0.0015%FSO/ °C |
| Temperature Effect Zero | < 0.0020%FSO/ °C |
| Atex | II 3D EX tc IIIC T60°C DC II 3G EX ec IIC GC |
|---|---|
| HighTemperature Cable | TeflonCable |
| High Temperature Range | 40°C to 90°C (Temperature Effect Output & Zero:<0.020%FSO/°C) |
| Accessories | Eye Bolt, Threaded Loading Button, Threaded Base Plate |
| Extra cable length | Specify extra length In Meters |
| Digital Version | Digital Output |
| Compatible Instrument | DLC-6M, DLC-6, Summing Junction Box |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.