Adi-Artech 60520-SS Single Point Table Top Load Cell
- Brand
- Adi-Artech
- Model number
- 60520-SS
- Category
- Load Cells
Adi-Artech strain gauge single point table top load cell, 0-10 Kgf to 0-100 Kgf for compression loads, in SS 17-4 PH stainless steel, IP65 sealed. For check weighing, bagging machines, table top scales.
Price and availability on request
Key features
- Complete Environmental Protection – Meets IP 65 class
- Stainless Steel 17-4 PH constructions
- Wide range of capacities from 25 KGF to 300 KGF
- Calibration in mV/V/Ω
- Can be customized to suit customer’s need
Specifications
| Applications | Check Weighing, Bagging Machines, Table Top Scales, Fisheries Scales, Food, Chemical and pharmaceutical weighing |
|---|
| Capacity range | 0-10Kgf to 0-100Kgf |
|---|---|
| Load direction | Compression only |
| Standard capacities | 25, 50, 75, 100, 300 – Kgf |
| Non-Linearity | < ±0.025% FSO (from 4% to 100% range) |
|---|---|
| Hysteresis | < ±0.05% FSO |
| Non-Repeatability | < ±0.03% FSO |
| Creep (30 minutes) | < ±0.03%FSO |
| Zero Balance | ±1.0%FSO |
| Output | 2.00 mV/V ± 0.2% |
|---|---|
| Excitation Voltage | Maximum 15 VDC (Suggested 5VDc / 10VDc) |
| Input Resistance | 390 ± 20.0 Ω (Ohms) |
| Output Resistance | 350 ± 10.0 Ω (Ohms) |
| Insulation Resistance | (100 VDC) > 1000 Mega Ω (Ohms) |
| Safe Overload Of Rated Capacity | 150% |
|---|---|
| Ultimate Overload of Rated Capacity | 250% |
| Allowable Side Load | 50% |
| Deflection | < 0.4 mm at FSO |
| Finish Product | Stainless Steel 17-4 ph |
| IP Rating | IP65 |
| Operating Temperature | 0°C to 60°C |
|---|---|
| Compensated Temperature | 10°C to 50°C |
| Temperature Effect Output | < 0.0025% FSO/ °C |
| Temperature Effect Zero | < 0.0030% FSO/ °C |
| Eccentric Load Effect | < 0.02 % of Output when 1/3 rated load placed at the edge of the specified size platter |
| Extra cable length | Specify extra length In Meters |
|---|---|
| Digital Version | Digital Output |
| Compatible Instrument | DLC-6M, DLC-6, Summing Junction Box |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.