Adi-Artech 60410-SS Single Point Platform Load Cell
- Brand
- Adi-Artech
- Model number
- 60410-SS
- Category
- Load Cells
Adi-Artech strain gauge single point platform load cell, 0 - 100 Kgf to 0 - 1500 Kgf for compression loads, in SS 17-4 PH stainless steel, IP65 sealed. For medium size platform scales, bag weighing, hopper weighing.
Price and availability on request
Key features
- Minimum Error for Off-center Loading
- Complete Environmental Protection – Meets IP 65 class
- Electro less Nickel Plated Tool Steel & stainless steel 17-4 PH constructions for hygienic and corrosive applications
- Wide range of capacities from 100 KGF to 1500 KGF
- Calibration in mV/V/Ω
- Can be customized to suit customer’s need
Specifications
| Applications | Medium Size Platform Scales, Bag Weighing, Hopper Weighing |
|---|
| Capacity range | 0 - 100 Kgf to 0 - 1500 Kgf |
|---|---|
| Load direction | Compression only |
| Standard capacities | 100, 200, 300, 500, 750, 1000, 1500 Kgf |
| Non-Linearity | < ±0.025% FSO (Full Scale Output) |
|---|---|
| Hysteresis | < ±0.02% FSO |
| Non-Repeatability | < ±0.01% FSO |
| Creep (30 minutes) | < ±0.03% FSO |
| Zero Balance | ±1.0% FSO |
| Output | 2.00 mV/V ± 0.2% |
|---|---|
| Excitation Voltage | Maximum 15 VDC (Suggested 5VDc / 10VDc) |
| Input Resistance | 390 ± 15.0 Ω (Ohms) |
| Output Resistance | 350 ± 5.0 Ω (Ohms) |
| Insulation Resistance | (100 VDC) > 1000 Mega Ω (Ohms) |
| Safe Overload Of Rated Capacity | 150% of Rated Capacity |
|---|---|
| Ultimate Overload of Rated Capacity | 250% of Rated Capacity |
| Allowable Side Load | 50% |
| Deflection | < 0.5 mm at FSO |
| Platter Size | 750 mm X 750 mm |
| Finish Product | 60410-Electro less nickel plated tool steel 60410-SS-Stain less Steel 17-4 ph |
| Tightening Torque | 5 m. kg |
| IP rating | Meets IP 65, IP 67 (Avavailable on request) (as per IS/IEC 60529:2001) |
| Operating Temperature | 0°C to 60°C |
|---|---|
| Compensated Temperature | 10°C to 50°C |
| Temperature Effect Output | < 0.0015% FSO/ °C |
| Temperature Effect Zero | < 0.0020% FSO/ °C |
| Extra cable length | Specify extra length In Meters |
|---|---|
| Digital Version | Digital Output |
| Compatible Instrument | DLC-6M, DLC-6, Summing Junction Box |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.