Adi-Artech 60410 Single Point Off-Center Load Cell

Model number
60410
Category
Load Cells

Adi-Artech strain gauge single point off-center load cell, 0 - 100 Kgf to 0 - 1500 Kgf for compression loads, in SS 17-4 PH stainless steel, IP65 sealed. For medium size platform scales, bag weighing, hopper weighing.

Price and availability on request

Request a quote

Sent with the product details: Adi-Artech 60410 Single Point Off-Center Load Cell.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Minimum Error for Off-center Loading
  • Complete Environmental Protection – Meets IP 65 class
  • Electro less Nickel Plated Tool Steel & stainless steel 17-4 PH constructions for hygienic and corrosive applications
  • Wide range of capacities from 100 KGF to 1500 KGF
  • Calibration in mV/V/Ω
  • Can be customized to suit customer’s need

Specifications

Product
ApplicationsMedium Size Platform Scales, Bag Weighing, Hopper Weighing
Rating
Capacity range0 - 100 Kgf to 0 - 1500 Kgf
Load directionCompression only
Standard capacities100, 200, 300, 500, 750, 1000, 1500 – Kgf
Performance
Non-Linearity< ±0.025% FSO (Full Scale Output)
Hysteresis< ±0.02% FSO
Non-Repeatability< ±0.01% FSO
Creep (30 minutes)< ±0.03% FSO
Zero Balance±1.0% FSO
Electrical
Output3.00 mV/V±0.05% (Customized Output available on request)
Excitation Voltage10 VDC- Maximum 15 VDC
Input Resistance390 ± 15 Ohms
Output Resistance350 ± 3 Ohms
Insulation Resistance> 1000 Mega Ohms at 50VDC
Structure
Safe Overload Of Rated Capacity150% of Rated Capacity
Ultimate Overload of Rated Capacity250% of Rated Capacity
Allowable Side Load50%
Deflection< 0.5 mm at FSO
Platter Size750 mm X 750 mm
Finish Product60410-Electro less nickel plated tool steel 60410-SS-Stain less Steel 17-4 ph
Tightening Torque5 m. kg
IP ratingMeets IP 65, IP 67 (Avavailable on request) (as per IS/IEC 60529:2001)
Temperature
Operating Temperature0°C to 60°C
Compensated Temperature0-60 °C
Temperature Effect Output< 0.0015% FSO/ °C
Temperature Effect Zero< 0.0020% FSO/ °C
Eccentric Load Effect< 0.02 % of Output when 1/3 rated load placed at 375 mm radius from the center of Load Cell
Options
Extra cable lengthSpecify extra length In Meters
Digital VersionDigital Output
Compatible InstrumentDLC-6M, DLC-6, Summing Junction Box

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.