Adi-Artech strain gauge single point platform load cell, 0-30 Kgf to 0-400 Kgf for compression loads, in SS 17-4 PH stainless steel, IP65 sealed. For chemical industries, process automations, check weigher.
Price and availability on request
Key features
- Complete Environmental Protection – Meets IP 65 class
- Electro less Nickel Plated Tool Steel & stainless steel 17-4 PH constructions
- Single point capability with minimum error for off center loading
- Wide range of capacities from 30 KGF to 400 KGF
- Calibration in mV/V/Ω
- Can be customized to suit customer’s need
Specifications
| Applications | Chemical Industries, Process Automations, Check Weigher, Bag Weighing, Marine scales, Process weighing- Hopper, Tank and Silos |
|---|
| Capacity range | 0-30Kgf to 0-400Kgf |
|---|---|
| Load direction | Compression only |
| Standard capacities | 30, 75, 100, 150, 200, 250, 300, 400 -KGF 500, 1000, 1500 (ON REQUEST) -KGF |
| Non-Linearity | < ±0.025% FSO (from 5% to 100% range) |
|---|---|
| Hysteresis | < ±0.02%FSO |
| Non-Repeatability | < ±0.01 % FSO |
| Creep (30 minutes) | < ±0.03% FSO |
| Zero Balance | ±1.0%FSO |
| Output | 2.00 mV/V ± 0.2% |
|---|---|
| Excitation Voltage | Maximum 15 VDC (Suggested 5VDc / 10VDc) |
| Input Resistance | 390 ± 15.0 Ω (Ohms) |
| Output Resistance | 350 ± 5.0 Ω (Ohms) |
| Insulation Resistance | (100 VDC) > 1000 Mega Ω (Ohms) |
| Safe Overload Of Rated Capacity | 150% |
|---|---|
| Ultimate Overload of Rated Capacity | 300% |
| AllowableSideLoad | 50% |
| Deflection | < 0.5 mm at FSO |
| Platter Size | 600 mm X 600 mm |
| Finish Product | 60310 – Electro less Nickel Plated Tool Steel 60310 SS – Stainless Steel 17-4 PH |
| Tightening Torque | 3 m. kg |
| IP rating | Meets IP 65, IP 67 (Avavailable on request) (as per IS/IEC 60529:2001) |
| Operating Temperature | 0°C to 60°C |
|---|---|
| Compensated Temperature | 10°C to 50°C |
| Temperature Effect Output | < 0.002 % FSO/ °C |
| Temperature Effect Zero | < 0.003 % FSO/ °C |
| Eccentric Load Effect | 60310 – < 0.02% of FSO at 1/3 rated load placed within 300mm radius from center of load cell 60310 SS – 0.3% of FSO at 1/3 rated load placed within 250mm radius from center of load cell |
| Extra cable length | Specify extra length In Meters |
|---|---|
| Digital Version | Digital Output |
| Compatible Instrument | DLC-6M, DLC-6, Summing Junction Box |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.