Model number
60310-SS
Category
Load Cells

Adi-Artech strain gauge single point platform load cell, 0-30 Kgf to 0-400 Kgf for compression loads, in SS 17-4 PH stainless steel, IP65 sealed. For chemical industries, process automations, check weigher.

Price and availability on request

Request a quote

Sent with the product details: Adi-Artech 60310-SS Single Point Platform Load Cell.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Complete Environmental Protection – Meets IP 65 class
  • Electro less Nickel Plated Tool Steel & stainless steel 17-4 PH constructions
  • Single point capability with minimum error for off center loading
  • Wide range of capacities from 30 KGF to 400 KGF
  • Calibration in mV/V/Ω
  • Can be customized to suit customer’s need

Specifications

Product
ApplicationsChemical Industries, Process Automations, Check Weigher, Bag Weighing, Marine scales, Process weighing- Hopper, Tank and Silos
Rating
Capacity range0-30Kgf to 0-400Kgf
Load directionCompression only
Standard capacities30, 75, 100, 150, 200, 250, 300, 400 -KGF 500, 1000, 1500 (ON REQUEST) -KGF
Performance
Non-Linearity< ±0.025% FSO (from 5% to 100% range)
Hysteresis< ±0.02%FSO
Non-Repeatability< ±0.01 % FSO
Creep (30 minutes)< ±0.03% FSO
Zero Balance±1.0%FSO
Electrical
Output2.00 mV/V ± 0.2%
Excitation VoltageMaximum 15 VDC (Suggested 5VDc / 10VDc)
Input Resistance390 ± 15.0 Ω (Ohms)
Output Resistance350 ± 5.0 Ω (Ohms)
Insulation Resistance(100 VDC) > 1000 Mega Ω (Ohms)
Structure
Safe Overload Of Rated Capacity150%
Ultimate Overload of Rated Capacity300%
AllowableSideLoad50%
Deflection< 0.5 mm at FSO
Platter Size600 mm X 600 mm
Finish Product60310 – Electro less Nickel Plated Tool Steel 60310 SS – Stainless Steel 17-4 PH
Tightening Torque3 m. kg
IP ratingMeets IP 65, IP 67 (Avavailable on request) (as per IS/IEC 60529:2001)
Temperature
Operating Temperature0°C to 60°C
Compensated Temperature10°C to 50°C
Temperature Effect Output< 0.002 % FSO/ °C
Temperature Effect Zero< 0.003 % FSO/ °C
Eccentric Load Effect60310 – < 0.02% of FSO at 1/3 rated load placed within 300mm radius from center of load cell 60310 SS – 0.3% of FSO at 1/3 rated load placed within 250mm radius from center of load cell
Options
Extra cable lengthSpecify extra length In Meters
Digital VersionDigital Output
Compatible InstrumentDLC-6M, DLC-6, Summing Junction Box

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.