Adi-Artech 60310-HS Hermetically Sealed Single Point Load Cell

Model number
60310-HS
Category
Load Cells

Adi-Artech strain gauge hermetically sealed single point load cell, 150, 200, 300, 400, 500, 600 Kgf for compression loads, in SS 17-4 PH stainless steel, IP68 sealed. For table top scales, fishries scales, check weigher.

Price and availability on request

Request a quote

Sent with the product details: Adi-Artech 60310-HS Hermetically Sealed Single Point Load Cell.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Complete Environmental Protection for gauge area – Meets IP 68 class. Protection class with SS cap laser welded
  • Electro less Nickel Plated Tool Steel & Stainless Steel 17-4 PH constructions
  • Laser welded cap for gauge area for hermetical sealing
  • Wide range of capacities from 150 KGF to 600 KGF
  • Calibration in mV/V/Ω
  • Can be customized to suit customer’s need

Specifications

Product
ApplicationsTable top scales, Fishries scales, Check weigher, Bagging machines, Dairy , Chemical and Pharmaceutical weighing
Rating
Capacity range150 , 200 , 300 , 400 , 500 , 600 Kgf
Load directionCompression only
Standard capacities150 , 200 , 300 , 400 , 500 , 600 Kgf
Performance
Non-Linearity< ±0.05% FSO (from 5% to 100% range)
Hysteresis< ±0.03% FSO
Non-Repeatability< ±0.05%FSO
Creep (30 minutes)< ±0.03%FSO
Zero Balance±5.0%FSO
Electrical
Nominal Output1.5 m V/V
Excitation VoltageMaximum 15 VDC (Suggested 5VDc / 10VDc)
InputResistance390 ± 20.0 Ω (Ohms)
OutputResistance350 ± 10.0 Ω (Ohms)
InsulationResistance(100 VDC) > 1000 Mega Ω (Ohms)
Structure
SafeOverload OfRatedCapacity150%
UltimateOverload ofRatedCapacity200%
Allowable Side Load50%
Platter Size500 mm X 500 mm
Finish ProductElectro less Nickel Plated Tool Steel or Stainless Steel 17-4 PH
IP ratingMeets IP 68 (as per IS/IEC 60529:2001)
Temperature
Operating Temperature0°C to 50°C
Compensated Temperature10°C to 50°C
Temperature Effect on Output< 0.005 % FSO/ °C
Temperature Effect on Zero< 0.004 % FSO/ °C
Eccentric Load Effect< 0.3% of FSO When1/3 rated load placed within 250mm radius from center of load cell
Options
Extra cable lengthSpecify extra length In Meters
Digital VersionDigital Output
Compatible InstrumentDLC-6M, DLC-6, Summing Junction Box