Adi-Artech 30510 Rope Tension Load Cell

Model number
30510

Adi-Artech strain gauge rope tension load cell, 0-1 to 0-30 Tf for tension loads, in nickel-plated tool steel, IP65 sealed. For elevator load monitor, vehicle pull test, ship bollard pull test.

Price and availability on request

Request a quote

Sent with the product details: Adi-Artech 30510 Rope Tension Load Cell.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • CE Rated
  • 0.1 Tf to 3.0 Tf capacities of load cells are offered for rope tension ranging from 1Tf to 30 Tf
  • Complete environmental protection IP-65 class provided
  • Standard output 1.0mV/V available
  • Can be provided to accommodate multi rope applications - up to 4 ropes

Specifications

Product
ApplicationsElevator load monitor, Specially designed for protecting cranes and hoists from overload, Tension measurement in stay ropes, suspension ropes and Rail way catenary ropes, Testing of starters/slip rings/brushes/clutches/brakes, Vehicle pull test, Ship Bollard pull test
Rating
Capacity range0-1 to 0-30 Tf
Load directionTension only
Standard capacities1.0 to 30.0 Tf. of Rope Tension
Performance
Non-Linearity< ± 5.0 % FSO for range up to 20% < ± 2.0 % FSO for range above 20%
Hysteresis< ±0.1% FSO
Non-Repeatability< ±0.1% FSO
Creep (30 minutes)< ±0.05% FSO
Electrical
Nominal Output1.0 m V/ V +/- 0.5
Excitation Voltage10 VDC- Maximum 15 VDC
Input Resistance390 ± 20 Ohms
Output Resistance350 ± 10 Ohms
Insulation Resistance(50VDC)> 1000 Mega Ohms(50 VDC)
Cable Length5 meters
Structure
Safe Overload of Rated Capacity150%
Ultimate Overload of Rated Capacity300%
Deflection< 0.4 mm at FSO
Finish & ConstructionElectro less Ni plated Tool Steel
Environmental Protection ClassIP65
Temperature
Compensated Temperature0-50 °C
Temperature Effect Output< 0.025% FSO/ °C
Temperature Effect Zero< 0.030% FSO/ °C
Options
Atex GradeII 3D EX tc IIIC T60°C DC II 3G EX ec IIC GC
High TempOperating Range – 100D°C
High Temp. CableTeflon Cable
Extra cable lengthSpecify extra length In Meters
Compatible InstrumentDLC-6M, DLC-6, Jumbo Display

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.