Adi-Artech 30210 Shear Beam Load Cell - Through Hole Loading

Model number
30210
Category
Load Cells

Adi-Artech strain gauge shear beam load cell - through hole loading, 0-30 Kgf to 0-10000 Kgf for compression loads, in nickel-plated tool steel, IP67 sealed. For hopper, tank, silo weighing, platform scale, steel weigher.

Price and availability on request

Request a quote

Sent with the product details: Adi-Artech 30210 Shear Beam Load Cell - Through Hole Loading.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Capacities are available from 0-30 Kgf. To 0-10,000 Kgf. for large platform scale applications
  • Also available in standardized output 2 +/-0.25% upon request, for multiple cell applications like floor scale , tank and hopper weighing
  • This can be customized to meet as per customer's specific requirements

Specifications

Product
ApplicationsHopper , Tank , Silo Weighing, Platform Scale, Steel Weigher, Onboard Weighing, Small Vehicle Weighing
Rating
Capacity range0-30 Kgf. To 0-10000 Kgf
Load directionCompression only
Standard capacities30, 50, 100, 150, 200, 250, 300, 500, 750 – Kgf. / 1, 1.5, 2, 2.5, 3, 5, 7.5, 10 – Tf
Performance
Non-Linearity< ±0.025% FSO
Hysteresis< ±0.02%FSO
Non-Repeatability< ±0.01%FSO
Creep (30 minutes)< ±0.03%FSO
Zero Balance±1.0%FSO
Electrical
Output3.00 mV/V±0.05% (Customized Output available on request)
Excitation Voltage10VDC-Maximum15VDC
Input Resistance392 ±15Ω (Ohms)
Output Resistance350 ±3Ω(Ohms)
Insulation Resistance(50 VDC) > 1000 Mega Ω (Ohms)
Structure
Safe Overload Of Rated Capacity150%
Ultimate Overload of Rated Capacity250%
Allowable Side Load50%
Deflection< 0.4 mm at FSO
Finish ProductElectro less Nickle plated Tool Steel
IP RatingIP67
Temperature
Operating Temperature0°C to 60°C
Compensated Temperature0-60°C
Temperature Effect Output< 0.0015%FSO/ °C
Temperature Effect Zero< 0.0020%FSO/ °C
Options
High TempOperating Range – 100D°C
High Temp. CableTeflon Cable
Extra cable lengthSpecify extra length In Meters
Mounting AccessoriesWM-I, WM-IV, WM-X
Digital VersionDigital Output
Compatible InstrumentDLC-6M, DLC-6, Summing Junction Box

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.